Setting a Lead-Free Reflow Profile

Measure what the board actually feels, not what the oven claims. Tune the curve until every joint on the hardest part of the board melts properly.

Owner
Assembly line lead
Reviewed
2026-08-21
Duration
60–90 min
Risk
Moderate

When to use this

Run this whenever the solder paste changes, the board design changes significantly, or the oven has been serviced. Also run it if joints start looking dull, grainy, or uneven.

A reflow profile is the temperature the board passes through over time. The oven heats the air. The board heats more slowly, and every board heats differently. So you measure the board.

Do not use this if you are running tin-lead paste. That melts near 183 °C and needs a completely different set of targets. Use the tin-lead procedure instead.

Before you start

Stop if: you cannot attach a thermocouple to the board itself. Air temperature and board temperature differ by tens of degrees. Profiling from the oven's own display is guessing.

The shape you are aiming for

217 °C liquidus 245 °C 45–90 s above liquidus Preheat Soak Reflow Cool time →
Four phases. Only the highlighted stretch actually melts solder — everything before it exists to get the board there evenly.
PhaseTargetWhy
Preheat ramp1–3 °C per secondFaster boils the flux and throws solder balls
Soak150–200 °C for 60–120 sLets thick and thin parts even out
Time above liquidus45–90 s above 217 °CLong enough to wet, short enough to spare parts
Peak235–245 °CComfortably above melt, below the part rating
Cool-downUp to 4 °C per secondFast gives shiny fine grain; too fast cracks parts

Procedure

  1. Read the targets off the paste datasheet

    Write down its ramp rate, soak window, peak, and time above liquidus. Every paste is slightly different. The datasheet wins any disagreement with the table above.

    Verify: you have five numbers written down, not four.

  2. Attach thermocouples to the scrap board

    Put one on the largest thermal mass, such as a big ground pad or a connector. Put one on the smallest part. Put one in open board area. Solder them down if you can; tape lifts and lies.

    Verify: tug each lead gently. Nothing moves.

  3. Run a baseline pass and log it

    Send the board through at the oven's current settings. Do not change anything yet. You need to know where you are starting from.

    Verify: all three channels logged a full curve with no dropouts.

    If it fails: a flat or spiking channel means a detached thermocouple. Reattach it and repeat this step.

  4. Fix the ramp first

    Check the steepest part of the preheat. If it exceeds 3 °C per second, lower the early zone temperatures or slow the belt.

    Verify: the fastest channel stays at or under 3 °C per second.

  5. Close the gap between channels during the soak

    Compare the hottest and coldest channels at the end of the soak. If they differ by more than about 10 °C, lengthen the soak.

    Verify: the spread across channels is under roughly 10 °C when the board leaves the soak.

  6. Set the peak against the weakest part on the board

    Raise the peak until the coldest channel clears 235 °C. Then check the hottest channel against the lowest maximum temperature of any part on the board. Overshooting cooks components, and the damage is permanent and often invisible until the product fails in the field.

    Verify: coldest channel above 235 °C, hottest channel below the lowest part rating.

    If it fails: if you cannot fit between those two numbers, stop. The board needs a layout or component change, not a hotter oven. Escalate to the design owner.

  7. Trim the time above liquidus

    Measure how long each channel stays above 217 °C. Aim for 45 to 90 seconds. Shorten by speeding the belt; lengthen by slowing it.

    Verify: every channel sits inside the 45–90 s window.

  8. Check the cool-down

    Measure the steepest downward slope. Keep it at or under 4 °C per second. Faster looks tempting but stresses ceramic parts.

    Verify: the drop never exceeds 4 °C per second.

  9. Run it twice more, then lock it

    Two consecutive passes must land inside every window. Save the recipe under a name that includes the paste and the board revision.

    Verify: two back-to-back passes pass on all channels, and the recipe is saved under its full name.

If it goes wrong

You seeIt usually meansDo this
Solder balls scattered around padsPreheat ramp too steep, flux spatteredSlow the ramp toward 1–2 °C per second
Dull, grainy jointsCooled too slowly, or too long above liquidusSpeed the cool-down; trim time above liquidus
Small parts standing on endOne pad melted before the otherLengthen the soak to even the board out
Voids under a ground padNot enough time for flux gas to escapePush time above liquidus toward 90 s
Brown flux residue, discoloured boardPeak too high or reflow too longLower the peak; re-check against part ratings
Cracked ceramic capacitorsCool-down too aggressiveReduce the cooling slope below 4 °C per second

Afterwards